西安交通大学能源与动力工程学院,西安,710049
网络首发:2014-11-10,
纸质出版:2014
移动端阅览
唐学强 1, 黄东 1, 龚勤勤 1, 等. 风冷冰箱蒸发器除霜特性及箱温回升的实验研究[J]. 西安交通大学学报, 2014,48(11):81-85+108.
Experimental Investigation for Dynamic Characteristics of Defrosting Process and Effect on Freezer Compartment Temperature in Domestic Frost-Free Refrigerator[J]. 2014, 48(11): 81-85+108.
唐学强 1, 黄东 1, 龚勤勤 1, 等. 风冷冰箱蒸发器除霜特性及箱温回升的实验研究[J]. 西安交通大学学报, 2014,48(11):81-85+108. DOI: 10.7652/xjtuxb201411014.
Experimental Investigation for Dynamic Characteristics of Defrosting Process and Effect on Freezer Compartment Temperature in Domestic Frost-Free Refrigerator[J]. 2014, 48(11): 81-85+108. DOI: 10.7652/xjtuxb201411014.
为了探究风冷冰箱除霜过程动态特性及其对箱温回升的影响
对某单循环风冷冰箱稳定运行时的除霜过程进行了实验研究
结果表明:在蒸发器温度升高到0 ℃的预热阶段
霜层堵塞翅片间隙
箱温基本无回升; 在温度维持在0 ℃左右的融霜阶段
除霜电加热被布置在蒸发器下方以及霜层“上疏下密”分布使底部霜层最早开始融化
融化结束时刻比顶部提前8 min
融霜时翅片间空气流通面积逐渐增大
进入箱体内部的热空气量增多
箱温在9.34 min内平缓上升5.7 ℃; 在温度高于0 ℃的排水阶段
因蒸发器右上方冷藏送风风道存在凸起
热空气会积聚在此处
导致阶段结束时该部位比左上温度高17.1 ℃
此时翅片间空气流通面积达到最大
箱温在6.5 min内快速上升6.6 ℃。
The defrosting process of a frost-free refrigerator is investigated experimentally
and the effect on the freezing compartment temperature is analyzed. The results show that in the pre-heating stage of the defrosting
the bottom temperature of the evaporator firstly rises to 0 ℃
and the freezing compartment temperature almost remains unchanged because the evaporator is blocked up by frost. In the melting-frost stage
the frost on the evaporator bottom begins to melt firstly and totally melts 8 min earlier than that on the top of the evaporator because the defrost heater is placed under the evaporator and the frost distribution is non-uniform
in fact
the frost on the evaporator top is greatly thinner than that on the bottom. During this stage
the frost melting results in increasing flow area between adjacent fins and the freezing compartment temperature gently rises by 5.7 ℃ in 9.34 min. In the draining-water stage beyond 0 ℃
the top-right temperature of the evaporator gets higher than the top-left temperature because the embossment of the air-supply duct of the refrigerating compartment leads to the warm air gathering there
and at the end of this stage the temperature difference between them increased significantly to 17.1 ℃. The freezing compartment temperature sharply rises by 6.6 ℃ in 6.5 min because the flow area increases to the maximum.
HUANG J M, HSIEH W C, KE X J, et al. The effects of frost thickness on the heat transfer of finned tube heat exchanger subject to the combined influence of fan types[J]. Applied Thermal Engineering, 2008, 28(7): 728-737.
AYNUR T N, INAN C, KARATAS H, et al. Real time upright freezer evaporator performance under frosted conditions[C]∥9th International Refrigeration and Air Conditioning Conference at Purdue. West Lafayette, USA: IRACC, 2002: 675-681.
ÖZKAN D B, ÖZIL E,(·overI)NAN C. Experimental investigation of the defrosting process on domestic refrigerator finned tube evaporators[J]. Heat Transfer Engineering, 2012, 33(6): 548-557.
MELO C, KNABBEN F T, PEREIRA P V. An experimental study on defrost heaters applied to frost-free household refrigerators[J]. Applied Thermal Engineering, 2013, 51(1): 239-245.
BANSAL P, FOTHERGILL D, FERNANDES R. Thermal analysis of the defrost cycle in a domestic freezer[J]. International Journal of Refrigeration, 2010, 33(3): 589-599.
KNABBEN F T, HERMES C J L, MELO C. In-situ study of frosting and defrosting processes in tube-fin evaporators of household refrigerating appliances[J]. International Journal of Refrigeration, 2011, 34(8): 2031-2041.
李成武, 钟金华, 陈星. 无霜冰箱化霜可靠性设计[J]. 电器, 2012(增刊): 142-147.
LI Chengwu, ZHONG Jinhua, CHEN Xing. Defrost design of no-frost refrigerators about reliability[J]. China Appliance, 2012(S1): 142-147.
宋新洲, 范志军. 利用冷藏室循环热进行化霜预处理的蒸发器化霜系统的试验研究[J]. 制冷技术, 2012, 32(1): 15-18.
SONG Xinzhou, FAN Zhijun. The experimental study of defrost system with cycling heat of refrigerating chamber pre-treatment program[J]. Chinese Journal of Refrigeration Technology, 2012, 32(1): 15-18.
汤晓亮, 王铁军, 杨帆. 风冷冰箱除霜控制技术研究与应用[J]. 制冷学报, 2013, 34(2): 49-54.
TANG Xiaoliang, WANG Tiejun, YANG Fan. Study on defrosting control technology of air cooled refrigerator[J]. Journal of Refrigeration, 2013, 34(2): 49-54.
刘志成, 赵渝生, 韦刚. 无霜冰箱化霜加热控制方案探讨[J]. 电器, 2013(增刊): 142-147.
LIU Zhicheng, ZHAO Yusheng, WEI Gang. Research on the control procedure of defrost heater of frost-free refrigerators[J]. China Appliance, 2013(S1): 142-147.
刘云,赵日晶,黄东.并联双循环风冷冰箱冷冻/冷藏切换时制冷剂迁移研究.2014,48(3):17-21.[doi:10.7652/xjtuxb 201403004]
马娟丽,刘昌海,周骞,等.膨胀阀开度对跨临界CO2制冷系统火用损失影响的实验研究.2014,48(3):12-16.[doi:10.7652/xjtuxb201403003]
刘华,沈胜强,龚路远,等.水平管降膜蒸发器温度损失的计算与分析.2014,48(4):90-94.[doi:10.7652/xjtuxb2014040 16]
王增丽,刘飞龙,程军明,等.单螺杆制冷压缩机单滑阀能量调节机构的几何特性分析.2014,48(7):117-123.[doi:10.7652/xjtuxb201407020]
吴建华,李育勇,王刚,等.丙烷滚动活塞压缩机指示图测量与性能分析.2014,48(3):6-11.[doi:10.7652/xjtuxb2014030 02]
张雷,车立新,毕胜山,等.天然气膨胀预冷混合制冷剂液化流程操作条件优化.2014,48(2):111-117.[doi:10.7652/xjtuxb201402019]
李盼,吴江,管晓宏,等.分析光伏电站输出特性的云遮挡太阳辐射模型.2013,47(8):61-67.[doi:10.7652/xjtuxb2013 08011]
龙延,魏进家,吕虓.不同倾角下平板型环路热管的实验研究.2013,47(5):38-43.[doi:10.7652/xjtuxb201305007]
蔡君伟,孙皖,李斌,等.-150 ℃逆布雷顿空气制冷机动态温降特性研究.2013,47(3):60-63.[doi:10.7652/xjtuxb 201303011]
王栋,李蒙,武卫东,等.小型CO2制冷系统最佳充注量的计算及实验研究.2013,47(3):80-84.[doi:10.7652/xjtuxb 201303015]
王猛,曹锋,夏春礼,等.HFC410A空调系统中两级滑片式膨胀机的实验研究.2013,47(1):27-31.[doi:10.7652/xjtuxb 201301006]
刘炅辉,李梦京,刘秀芳,等.以R22为冷却剂的闭式循环相变喷雾冷却实验研究.2013,47(1):132-136.[doi:10.7652/xjtuxb201301025]
0
浏览量
5
下载量
3
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621