为了抑制无输出隔离变压器中由于控制漂移、器件性能不一致等原因使得三相逆变器输出中包含的直流分量
提出了两种直流分量的抑制策略并进行了对比分析。第一种是在dq坐标系下采用带通滤波器检测输出电流直流分量并进行PI调节
然后补偿SVPWM脉宽的策略; 第二种是在abc坐标系下采用滑动平均滤波检测出输出电流的直流分量并进行PI调节
然后补偿SVPWM脉宽的策略。通过理论分析和建模仿真对两种策略进行了对比分析
并在450 kW的三相逆变器上做了一系列实验。结果表明
采用滑动平均滤波策略在不同负载下对输出直流分量的抑制都有更好的效果
而带通滤波策略在轻载下抑制效果不能达标
重载下抑制效果也没有滑动平均法好。
To suppress the output DC component of three-phase inverter without output transformers due to control drift and inconsistent device performances
two modulation strategies are comparatively proposed. In the first modulation strategy
band-pass filter is adopted to detect the DC component in total output current
then the SVPWM pulse width is compensated with PI control in dq coordinate system. In the second strategy
slip average filter is chosen to detect the DC component
then SVPWM pulse width is compensated with PI control in abc coordinate system. Following the discussions for modeling and simulating
the experiments for 450 kW three-phase inverter are conducted and the results indicate that the slip average filter better suppresses the output DC component
while band-pass filter does not meet the suppressing standards under light load and works worse than the former under heavy load.
SALAS V, OLIAS E, ALONSO M, et al. DC current injection into the network from PV grid inverters[C]∥IEEE Proceedings of 4th World Conference of Photovoltaic Energy Conversion. Piscataway, NJ, USA: IEEE, 2006: 2371-2374.
HE Zhongyi, XING Yan. Distributed control for UPS modules in parallel operation with RMS voltage regulation[J]. IEEE Transactions on Industrial Electronics, 2008, 55(8): 2860-2869.
陈良亮, 肖岚, 胡文斌, 等. 逆变器输出电压直流分量产生原因与抑制方法[J]. 电力电子技术, 2003, 37(5): 27-29.
CHEN Liangliang, XIAO Lan, HU Wenbin, et al. Reasons and restraining methods for DC bias in inverter output voltage[J]. Power Electronics, 2003, 37(5): 27-29.
LI Peng, DAN Bai, YONG Kang, et al. Research on three-phase inverter with unbalanced load[C]∥Proceeding of IEEE APEC. Piscataway, NJ, USA: IEEE, 2004: 128-133.
PINHEIRO H, FBOTTER O N, PINHEIR O Jr. A digital controller for single-phase UPS inverters to reduce the output DC component[C]∥Proceedings of IEEE Annual Power Electronics Specialists Conference. Piscataway, NJ, USA: IEEE, 2004: 1311-1314.
徐德鸿. 电力电子系统建模及控制[M]. 北京: 机械工业出版社, 2010: 111-149.
张亚宁, 朱涛, 傅军, 等. 一种基于TMS320F2812的高精度A/D转换器的设计[J]. 测控技术, 2013, 32(3): 26-28.
ZHANG Yaning, ZHU Tao, FU Jun, et al. Develop-ment of a high-precision A/D converter based on TMS320F2812[J]. Measurement and Control Technology, 2013, 32(3): 26-28.
ARMSTRONG M, ATKINSON D J. Auto-calibrating DC link current sensing technique for transformerless, grid connected, H-bridge inverter systems[J]. IEEE Transactions on Power Electronics, 2006, 21(5): 1385-1394.
0
浏览量
4
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621