Boil-off gas(BOG)compressors operate at low suction temperature and suffer from great temperature change when the working condition changes. In this study
the FEM simulation of heat transfer in a BOG compressor was performed
and the static and periodic transient temperature fields and their changes were obtained during the compressor starting both under ambient condition and precooling conditions. The results show that
when the BOG compressor operates steadily
the average temperatures in the suction chamber and the discharge chamber of the cylinder are -97 ℃ and -21 ℃
respectively
and the amplitude of temperature fluctuation is less than 0.1 ℃ in the periodic transient temperature field. In addition
the maximum temperature difference in the cylinder is 53.5 ℃ when the compressor starts at -30 ℃ while it is 87.1 ℃ when the compressor starts under the ambient condition(at 30 ℃).