提出了一种基于参数识别的双端带并联电抗器的输电线路纵联保护原理.在故障附加状态网络的基础上
为内部故障和外部故障建立了具有相同形式的电感模型.利用参数识别的原理求取模型中的电感参数
并计算其对应感抗.内部故障时
它反映两端的系统感抗
为一个较小的负数; 外部故障时
它反映并联电抗器的感抗
是一个较大的正数.根据所得感抗的符号和大小来区分内部故障和外部故障.该原理采用了基于线路π模型的解微分方程算法
不受非周期分量和过渡电阻的影响
整定简单.EMTP和动模实验数据仿真验证了该方法的有效性.
A new type of pilot protection for transmission line with shunt reactors at double terminal following parameter identification is proposed. Based on the fault component nets
R-L models with the same pattern are established for the internal fault state and the external fault state. The inductance in R-L models can be evaluated by parameter identification. When an internal fault occurs
the inductance reflects the impedance of the system source as a smaller minus
and when an external fault occurs
it signs the inductance of reactor as a greater positive
thus the internal fault and external fault are distinguished. The criterion is not influenced by the transient components and fault resistance
and also can be easily set. EMTP simulation shows the higher sensitivity
reliability and effectiveness.
朱声石.高压电网继电保护原理与技术[M].北京:中国电力出版社,2005:1-2.
伍叶凯,邹东霞.电容电流对差动保护的影响及补偿方案[J].继电器,1997,25(4):4-8.
WU Yekai,ZOU Dongxia.The influence of capacitance current to differential protection and its compensation scheme[J].Relay,1997,25(4):4-8.
索南加乐,张怿宁,齐军,等.基于时域电容电流补偿的电流差动保护研究[J].西安交通大学学报,2005,39(12):1370-1374.
SUONAN Jiale, ZHANG Yining, QI Jun, et al. Current differential protection based on time-domain algorithm of capacitive current compensating[J].Journal of Xi'an Jiaotong University,2005,39(12),1370-1374.
郑玉平,吴通华,丁琰,等.基于贝瑞隆模型的线路差动保护实用判据[J].电力系统自动化,2004,28(23):50-55.
WU Tonghua, ZHENG Yuping, DING Yan,et al. Applied criterion of current differential protection based on Bergeron mode[J]. Automation of Electric Power, 2004,28(23):50-55.
文明浩,陈德树,尹项根.远距离输电线路等传变瞬时值差动保护[J].中国电机工程学报,2007,27(28):59-65.
WEN Minghao, CHEN Deshu, YIN Xianggen.Long transmission line current differential protection by using instantaneous value after equal transfer processes[J].Proceedings of the CSEE,2007,27(28):59-65.
张武军,何奔腾,沈冰.特高压带并联电抗器的行波差动保护[J].中国电机工程学报,2007,27(10):56-61.
ZHANG Wujun, HE Benteng, SHEN Bing. Traveling-wave differential protection on UHV transmission line with shunt reactor[J]. Proceedings of the CSEE,2007,27(10):56-61.
索南加乐,王向兵,孟祥来,等.基于R-L模型的参数识别快速方向元件[J].西安交通大学学报,2006, 40(6):690-693.
SUONAN Jiale, WANG Xiangbing, MENG Xianglai,et al. Quick directional element based on R-L model parameter identification[J]. Journal of Xi'an Jiaotong University,2006,40(6),690-693.
索南加乐,薛晓辉,高峰,等.小电流接地系统单相故障选线的研究[J].西安交通大学学报,2008,42(4):471-475
SUONAN Jiale, XUE Xiaohui,GAO Feng et al. Fault line selection in non solid earthed network[J].Journal of Xi'an Jiaotong University,2008,42(4):471-475.
索南加乐,杨铖,杨忠礼,等.基于模型识别的输电线路纵联保护新原理[J].电力系统自动化学,2008,32(24):30-34.
SUONAN Jiale, YANG Cheng, YANG Zhongli, et al. New type of transmission line pilot protection base on modelidentification[J]. Automation of Electric Power, 2008,32(24):30-34.
索南加乐,康小宁,宋国兵,等.基于参数识别的继电保护原理初探[J].电力系统及其自动化学报,2007,19(1):14-20.
SUONAN Jiale, KANG Xiaoning, SONG Guobing,et al. Survey on relay protection using parameter identification[J]. Proceedings of the CSU-EPSA, 2007,19(1):14-20.
基于形态梯度的输电线电流行波比较式超高速保护.西安交通大学学报,2007,41(04):484-488.
一种新的高压线路振荡选相元件.西安交通大学学报,2007,41(08):949-953.
基于励磁电感参数识别的变压器励磁涌流判别方法.西安交通大学学报,2007,41(10):1214-1218.
输电线路超高速保护中小波算法的研究.西安交通大学学报,2008,42(02):194-198.
带可控串补和可调电抗器输电线路纵联保护新原理.西安交通大学学报,2008,42(10):1259-1263.