针对变电站接地网实际敷设情况往往与施工图纸有所出入、可能造成诊断结果具有较大误差的情况
在传统电路诊断模型的基础上考虑了接地网腐蚀特性
即地理位置越接近的导体被腐蚀的程度越相近
并提出局部差异性腐蚀指标表示支路电阻腐蚀倍数的相近程度
从而建立了接地网故障诊断的增广线性模型
同时运用基于奇异值分解法分解的最佳降秩逼近定理解决模型中方程组等式两端的不相容性.为校正诊断模型中存在的扰动对诊断结果的影响
采用了基于约束总体最小二乘算法的优化算法
对明晰支路和模糊支路分别迭代
在已知设计模型与实际支路敷设有偏差的情况下得出了较为满意的解.仿真计算结果验证了所提方法的正确性和有效性.
A discrepancy between the actual installation of substation grounding grids and the design drawings often leads to bigger error in the diagnostic results. Based on the traditional circuit method
the corrosion diagnosis algorithm is improved to take the corrosion characteristics into account
which means that the branches connected to the same node have the similar corrosion extent range. Therefore
an augmented linear model is proposed with localized difference corrosion index. And the best reduced-rank approximation theorem is adopted to ensure the compatibility of the equations. To solve the novel model
the total least squares algorithm is chosen to reduce the deviation carried by the disturbance factors in the model. The simulation results show the validity of this approach.
DAWALIBI F. Electromagnetic fields generated by overhead and buried short conductors: part 2 [J]. IEEE Trans Power Delivery, 1986, 1(4):112-119.
ZHANG Bo, ZHAO Zhibin, CUI Xiang, et al. Diagnosis of breaks in substation's grounding grid by using the electromagnetic method[J]. IEEE Trans on Magnetics, 2002, 38(2):473-476.
刘庆珍, 蔡金锭. 电力系统接地网故障的无伤检测方法[J]. 高电压技术, 2003, 29(6):47-48,51.
LIU Qingzhen, CAI Jinding. Fault detection of grounding grid of power system[J]. High Voltage Engineering, 2003, 29(6):47-48, 51.
张晓玲, 陈先禄. 优化技术在发、变电所接地网故障诊断中的应用[J]. 高电压技术, 2000, 26(4):64-66.
ZHANG Xiaoling, CHEN Xianlu. The technique of the optimization applied in the grounding grid's failure diagnosis[J]. High Voltage Engineering, 2000, 26(4):64-66.
ZENG Rong, HE Jinliang, HU Jun, et al. The theory and implementation of corrosion diagnosis for grounding system[C]∥IEEE Industry Applications Society Annual Meeting. Pittsburgh, PA, USA:IEEE, 2002:1120-1126.
刘健, 王建新, 王森. 一种改进的接地网故障诊断算法及测试方案评价[J]. 中国电机工程学报, 2005, 25(3):71-77.
LIU Jian, WANG Jianxin, WANG Sen. An improved algorithm of corrosion diagnosis for grounding grid its evaluation[J]. Proceedings of the CSEE, 2005, 25(3):71-77.
刘健,王树奇,李志忠,等. 基于网络拓扑分层约简的接地网腐蚀故障诊断[J]. 中国电机工程学报, 2008, 28(16):122-128.
LIU Jian, WANG Shuqi, LI Zhizhong, et al. Grounding grids corrosion diagnosis based on hierarchical simplification of network topology [J]. Proceedings of the CSEE, 2008, 28(16):122-128.
罗先觉. 一种同时求解电路全部响应对全部参数灵敏度的算法[J]. 西安交通大学学报, 1997, 21(12):1-7.
LUO Xianjue. An algorithm of evaluating simultaneously the sensitivities of all circuit responses with respect to all parameters[J]. Journal of Xi'an Jiaotong University, 1997, 21(12):1-7.
STARZYK J A, PANG J, MANETTI S, et al. Finding ambiguity groups in low testability analog circuits[J]. IEEE Transactions on Circuits and Systems I: Fundamental Theory and Applications, 2000, 47(8):1125- 1137.
LIU E, KAO W, FELT E, et al. Analog testability analysis and fault diagnosis using behavioral modeling[C]∥Proceedings of the 1994 IEEE Conference on Custom Integrated Circuits. Piscataway,NJ,USA:IEEE, 19994: 413-416.
ZHOU Mi, WANG Jianguo, LIU Yang, et al. Causes, forms and remedies of substation grounding grid corrosion[C]∥International Conference on High Voltage Engineering and Application. New Orleans, USA: [s.n.], 2008:186-189.
GOLUB G H, VAN LOAN C F. Matrix computations [M]. Baltimore, Maryland, USA: The Johns Hopkins University Press, 1983: 16-19.
魏木生. 广义最小二乘问题的理论和计算[M]. 北京:科学出版社, 2006:107-115.
LIU Liqiang, LUO Xianjue, NIU Tao, et al. Grounding grids corrosion diagnosis based on large change sensitivity[C]∥The Fifth International Conference on Information Assurance and Security. Atlanta, USA: [s.n.], 2009:71-74.
利用增量二次规划和启发式方法的电力系统动态无功优化. 西安交通大学学报,2010,44(8):106-111.
利用线路两端电压差的输电线路相位纵联保护. 西安交通大学学报,2010,44(8):83-89.
交直流混联系统对距离保护暂态超越的影响及解决措施. 西安交通大学学报,2010,44(4):57-61.
故障全量的分相复合阻抗输电线路纵联保护原理. 西安交通大学学报,2010,44(2):92-97.
基于模型识别的平行线路零序方向元件. 西安交通大学学报,2010,44(2):102-107.
双端带并联电抗器的输电线路纵联保护. 西安交通大学学报,2009,43(10):99-103.
继电保护装置信号端口电磁干扰传播通道的建模与仿真. 西安交通大学学报,2009,43(10):104-108.