新型功能材料及其制备科学国家重点实验室, 宁波大学材料科学与化学工程学院,浙江,宁波,315211
网络首发:2010-07-10,
纸质出版:2010
移动端阅览
干宁 1, 倪敏君 2, 郑磊 3, 等. 采用抗体包被纳米金多层自组装膜的HCG安培免疫传感器[J]. 西安交通大学学报, 2010,44(7):114-119.
Amperometric Immunosensor for Human Chorionic Gonadotrophin Based on Antibody Coated Nano Gold Multilayer Modified Electrode[J]. 2010, 44(7): 114-119.
研制了一种采用人绒毛膜促性腺激素抗体(anti-HCG)包被巯基丁二酰胺(HL)/纳米金(AuNPs)多层膜修饰金电极的免疫传感器(Au|{HL/AuNPs}
n
-anti-HCG)
用于检测人唾液中的HCG.通过层层自组装技术在Au电极表面交替修饰多层{HL/AuNPs}
n
膜
再通过膜内的AuNPs吸附anti-HCG
构筑了HCG安培免疫传感器.以K
3
Fe(CN)
6
为探针
在pH 7.0的PBS缓冲液中加入HCG
随着HCG与电极表面anti-HCG发生特异性免疫反应
形成的抗原/抗体免疫复合物使得K
3
Fe(CN)
6
在电极表面的响应电流减小
减小量(I
p
)与膜表面的免疫反应程度相关
以此作为HCG定量的依据.对各修饰电极表面进行了表征和定量分析.实验表明:该免疫传感电极中{HL/AuNPs}
n
膜内存在的大量AuNPs显著增加了anti-HCG吸附量
从而使得其HCG检测范围变宽(0.1~100 mg/L)
检出下限为0.056 mg/L(3σ).
An amperometric immunosensor for human chorionic gonadotrophin(HCG)in the saliva is developed based on HCG antibody(anti-HCG)coated mercapto succinic amide(HL)/gold nanoparticles(AuNPs)multilayer membrane modified Au electrode. HL/AuNPs monolayers are modified alternatively and form multiple membranes through Au-NH
2
and Au-S bonds by layer-by-layer self-assembly technology. K
3
Fe(CN)
6
is employed as electron probe for detection. The antigen-antibody immune complex formed on the electrode surface is able to hinder electron transport
so the redox current of K
3
Fe(CN)
6
is decreased. The decreased value of ΔI
p
is related to the extent of immune-reaction on membrane surface
which serves as the quantitative basis of HCG content. The experimental results show that multilayer AuNPs membrane can adsorb more anti-HCG
and obviously broaden the linear detection range of HCG to 0.1-100 mg/L with detection limit of 0.056 mg/L(3σ).
CHAI Rong, YUAN Ruo, CHAI Yaqin, et al. Amperometric immunosensors based on layer-by-layer assembly of gold nanoparticles and methylene blue on thiourea modified glassy carbon electrode for determination of human chorionic gonadotrophin [J]. Talanta, 2008,74(5):1330-1336.
CHIAPPIN S, ANTONELLI G, GATTI R, et al. Saliva specimen: a new laboratory tool for diagnostic and basic investigation [J]. Clinica Chimica Acta, 2007,383(1/2):30-40.
CHEN Jin, YAN Feng, DAI Zong, et al. Reagentless amperometric immunosensor for human chorionic gonadotrophin based on direct electrochemistry of horseradish peroxidase [J]. Biosens, Bioelectron, 2005,21(2):330-336.
干宁,李榕生,陈亚东,等. 基于抗体包被金磁纳米微粒修饰电极的HIVp24和gp36安培联检芯片[J].西安交通大学学报,2009,43(7):115-119.
GAN Ning, LI Rongsheng, CHEN Yadong, et al. Micro fluidic amperometric immunosensor chip for HIV-p24 and gp36 antigens based on gold magnetic nanoensemble electrode [J]. Journal of Xi'an Jiaotong University, 2009,43(7):115-119.
CHEN Jin, TANG Jinhai, YAN Feng, et al. A gold nanoparticles/sol-gel composite architecture for encapsulation of immunoconjugate for reagentless electrochemical immunoassay [J]. Biomaterials, 2006,27(10):2313-2321.
CHEN Jin, YAN Feng, TANG Jinhai, et al. Gold nanoparticles doped three-dimensional sol-gel matrix for amperometric human chorionic gonadotrophin immunosensor [J]. Electroanalysis, 2006,18(17):1696-1702.
GUO Wei, HU Naifei. Interaction of myoglobin with poly(methacrylic acid)at different pH in their layer-by-layer assembly films: an electrochemical study [J]. Biophysical Chemistry, 2007,129(2/3):163-171.
IDEGAMI K, CHIKAE M, KERMAN K, et al. Gold nanoparticle-based redox signal enhancement for sensitive detection of human chorionic gonadotropin hormone [J]. Electroanalysis, 2008,20(1):14-21.
WARAKORN L, PROESPICHAYA K, BO M, et al. A reusable capacitive immunosensor for human chorionic gonadotrophin detection using thiourea modified gold electrode [J]. Analytica Chimica Acta, 2006,561(1/2):55-61.
YANG Gongmei, CHANG Yanbin, YANG Hui, et al. The preparation of reagentless electrochemical immunosensor based on a nano-gold and chitosan hybrid film for human chorionic gonadotrophin [J]. Analytica Chimica Acta, 2009,644(1/2):72-77.
0
浏览量
4
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621