西安交通大学能源与动力工程学院,西安,710049
网络首发:2008-05-10,
纸质出版:2008
移动端阅览
晏刚, 颜俊, 王维, 等. 自复叠制冷循环双温冰箱设计的理论研究[J]. 西安交通大学学报, 2008,42(5):551-555.
晏刚, 颜俊, 王维, et al. Theoretical Study on Design of Two-Stage Temperature Refrigerator Using Auto-Cascade Refrigeration Cycle[J]. 2008, 42(5): 551-555.
为了给冰箱提供不同的间室温度来满足储存要求
将采用非共沸混合制冷剂的自复叠制冷循环应用于双温冰箱系统
研究了两间室蒸发器出口温度、冷凝器出口温度、冷藏室与冷冻室制冷量比例及冷凝蒸发器高压侧出口过冷度的变化对冰箱系统优化设计的影响.结果表明:系统性能系数随着冷藏室和冷冻室蒸发器出口温度的降低、冷凝器出口温度的升高而减小; 提高两间室制冷量的比例可增大性能系数
但压缩机耗功和压力比也同时增大; 增大冷凝蒸发器高压端出口侧制冷剂的过冷度可以减小压缩机耗功
提高系统性能系数.研究结果对于自复叠双温冰箱的实际推广提供了参考.
A two-stage temperature refrigerator using auto-cascade refrigeration cycle and non-azeotropic mixture refrigerant was proposed. The system parameters including the outlet temperatures of the evaporators and the condenser
the refrigerating capacity ratio of the two compartments and the subcooling degree at outlet of the evaporative condenser were analyzed to optimize the design of the refrigerator. The results show that as the outlet temperatures of the fridge evaporator and the freezer evaporator decrease
or the condensation temperature increases
the coefficient of performance(C
COP
)decreases. Moreover
increasing the refrigerating capacity ratio can improve the system C
COP
but the compressor power consumption and the pressure ratio increases. In addition
as the subcooling degr
ee at the high-pressure outlet of the evaporative condenser increases
the compressor power decreases and the system C
COP
rises.
岳云,贾冰.国外模糊技术、模糊家电发展现状[J].电子产品世界,2000(4):23-26.
YUE Yun, JIA Bing. The developing status of foreign fuzzy technology and fuzzy household electric appliance [J]. The World of Electric Production, 2000(4):23-26.
ROSE R J. Testing of domestic two-evaporator refrigerators with azeotropic refrigerator mixtures[J]. ASHRAE Transactions,1992,98(2):40-43.
博西文.电冰箱的双循环制冷系统[J].家用电器,2001(1):25-26.
BO Xiwen. The dual refrigerating cycle system of refrigerator [J]. Household electric appliance, 2001(1): 25-26.
王勇,朱玉群,李文林,等.家用冰箱制冷循环的发展概况[J].流体机械,2003,31(8):47-52.
WANG Yong, ZHU Yuqun, LI Wenlin, et al. Development tendency of domestic refrigerator cycle [J]. Fluid Machinery, 2003, 31(8): 47-52.
吴业正.制冷与低温技术原理 [M].北京:高等教育出版社,2004.
刘志勇,陈光明,王勤,等.具有精馏装置的自动复叠制冷循环的试验研究 [J].流体机械,2004,32(10):50-52.
LIU Zhiyong, CHEN Guangming, WANG Qin, et al. Experimental study on auto-cascade refrigeration system with rectification column [J]. Fluid Machinery, 2004, 32(10):50-52.
宋世亮,沈永年,王兆华.CO2用于自然复叠制冷系统的理论分析 [J].低温与特气,2004,22(5):13-16.
SONG Shiliang, SHEN Yongnian, WANG Zhaohua. Theoretical analysis on autocascade refrigeration systems using carbon dioxide [J]. Low Temperature and Specialty Gases, 2004, 22(5): 13-16.
KIM S G, KIM M S. Experiment and simulation on the performance of an autocascade refrigeration system using carbon dioxide as a refrigerant [J]. Int J Refrig, 2002, 25(8): 1093-1101.
陈光明,张绍志,王勤.深度制冷方法及其装置: 中国,02110664.9 [P].2002-08-14.
晏刚.一种单机多温蒸气压缩式制冷装置:中国,03262516.2 [P].2004-12-29.
晏刚,任挪颖,徐荣吉,等.船舶多温冷库新型自复叠制冷循环的研究 [J].西安交通大学学报,2006,40(5):526-538.
YAN Gang, REN Nuoying, XU Rongji,et al. Studies on a new type of auto-refrigerating cascade circle for marine multi-stage temperature refrigerator [J]. Journal of Xi'an Jiaotong University, 2006, 40(5): 526-538.