西安交通大学电气工程学院,西安,710049
网络首发:2010-02-10,
纸质出版:2010
移动端阅览
杨铖, 索南加乐, 孙成. 基于模型识别的平行线路零序方向元件[J]. 西安交通大学学报, 2010,44(2):102-107.
A New Type of Zero-Sequence Directional Relay Based on Model Recognition for Parallel Lines[J]. 2010, 44(2): 102-107.
分析指出
平行线路区内故障时的零序电源可等效为一个位于区内的电压源
零序电路符合电感模型
线路区外故障时的零序电源则可等效为一区内电压源和一区外电压源的叠加
零序电路不再满足电感模型.所以区内故障时
电感模型误差很小
区外故障时
电感模型误差很大.通过计算模型误差
结合传统的零序方向元件
提出了一种基于模型识别的平行线路零序方向元件的新原理
能够有效防止区外故障时的保护误动
当本线内部故障时
保护的灵敏度随动作时间自适应提高
可以快速动作切除故障.理论分析和EMTP仿真实验表明
新原理利用全部故障暂态信息
在时域中计算而无需滤波
区内故障时保护动作灵敏
区外故障时保护则快速闭锁
可靠性很高.
The mal-operation of pilot zero-sequence direction protection working on parallel lines is usually caused by the zero-sequence mutual inductance.By analyzing zero-sequence network of parallel lines
an inductance circuit model is established for the internal fault
and a novel zero-sequence directional relay based on model recognition is proposed for parallel lines. When the internal fault occurs
the model error is small and decreases quickly
and when the external fault occurs
the model error is large and oscillates.By computing the model error
the performance of the conventional zero-sequence directional relay is improved. The theoretic analysis demonstrates the validation of the new relay.
沈国荣.工频变化量方向继电器原理的研究[J].电力系统自动化,1983,7(1):28-38.
SHEN Guorong. Study of principle of power frequency variation directional relay[J].Automation of Electric Power System,1983,7(1):28-38.
RADOJEVIC Z M,TERZIJ A V V, DJURIC M B. Numerical algorithm for overhead lines arcing faults detection and distance and directional protection[J]. IEEE Trans on Power Delivery,2000,15(1):31-37.
索南加乐,孟祥来,陈勇,等.基于故障类型的零序方向元件[J].中国电机工程学报,2007, 27(1):25-30.
SUONAN Jiale, MENG Xianglai, CHEN Yong, et al. A novel zero sequence directional element based on fault type[J].Proceedings of the CSEE, 2007, 27(1):25-30.
汪萍,陈久林.纵联零序方向保护误动原因分析及其对策[J].电力自动化设备,2007,27(7):122-125.
WANG Ping, CHEN Jiulin. Analysis of longitudinal zero-sequence direction protection misoperation and its countermeasures[J].Electric Power Automation Equipment,2007,27(7):122-125.
李一泉,焦邵麟,张弛,等.平行线路纵联零序方向保护安全性分析[J].电力系统自动化,2008,32(6):104-107.
LI Yiquan, JIAO Shaolin, ZHANG Chi, et al. Safety analysis on pilot zero sequence direction relay applied in parallel wrong judgment of zero-sequence directional relay applied in parallel lines[J].Automation of Electric Power System,2008,32(6):104-107.
樊占峰,叶东印,李瑞生,等.平行线弱电强磁模型下零序方向元件改进[J].电力系统自动化,2008,32(17):100-103.
FAN Zhanfeng, YE Dongyin, LI Ruisheng, et al. Improvement of zero-sequence directional relay for the parallel line with magnetically strong and electrically weak connection[J].Automation of Electric Power System,2008,32(17):100-103.
邵文权,加玛力汗,宋国兵,等.基于电容参数识别的永久性故障判别方法[J].西安交通大学学报,2008,42(6):708-712.
SHAO Wenquan, JIAMA Lihan, SONG Guobing, et al. Permanent fault identification method based on capacitance parameter[J].Journal of Xi'an Jiaotong University, 2008,42(6):708-712.
索南加乐,王向兵,孟祥来,等.基于R-L模型的参数识别快速方向元件[J].西安交通大学学报,2006,40(6):689-693.
SUONAN Jiale, WANG Xiangbing, MENG Xianglai,et al.Quick directional element based on R-L model parameter identification[J].Journal of Xi'an Jiaotong University,2006,40(6):689-693.
索南加乐,薛晓辉,高峰,等.小电流接地系统单相接地故障选线的研究[J].西安交通大学学报,2008,42(4):472-476.
SUONAN Jiale, XUE Xiaohui, GAO Feng, et al. Fault line selection in non-solid earthed network[J].Journal of Xi'an Jiaotong University,2008,42(4):472-476.
索南加乐,陈福锋,齐军,等.串补线路故障点位置的模型识别方法 [J].中国电机工程学报,2005,25(1):66-72.
SUONAN Jiale,CHEN Fufeng,QI Jun,et al. New method for identifying the fault location on series compensated lines based on different fault models[J].Proceedings of the CSEE,2005,25(1):66-72.
索南加乐,杨铖,杨忠礼,等. 基于模型识别的输电线路纵联保护新原理[J].电力系统自动化,2008,32(24):30-34.
SUONAN Jiale, YANG Cheng, YANG Zhongli, et al. New type of transmission line pilot protection based on model identification[J]. Automation of Electric Power Systems, 2008,32(24):30-34.