华中科技大学能源与动力工程学院,武汉,430074
网络首发:2010-03-10,
纸质出版:2010
移动端阅览
盖东兴, 刘伟, 刘志春, 等. 环路热管系统温度波动的机理研究[J]. 西安交通大学学报, 2010,44(3):26-31.
Mechanism Research on Temperature Oscillation of Loop Heat Pipe[J]. 2010, 44(3): 26-31.
从冷凝器两相区的水动力学不稳定性入手
分析了环路热管的温度波动机理
得出了冷凝器两相区不稳定性是系统温度波动的源动力之一.实验发现以甲醇为工质的环路热管系统温度波动集中发生在热负荷介于12~60 W时
而在该区间之外的较低和较高热负荷范围
系统能够平稳运行
这和理论分析结果相符合.另外
系统温度波动剧烈程度随着系统工质充灌量的增加而明显增强.与以甲醇为工质的环路热管相比
采用汽化潜热较小的丙酮为工质时
系统发生温度波动的热负荷范围变窄
同时温度波动剧烈程度明显降低.
The mechanism of temperature oscillation in a loop heat pipe was analyzed on the basis of the instability of two-phase flow at the entrance of a condenser
and the results show that the instability of two-phase flow is one of the sources of temperature oscillation. The experimental results indicate that temperature oscillation occurs as the heat load of the loop heat pipe system is in a range of 12-60 W while the system can operate stably when the load is outside the range
matching the theoretical analysis. Further
the severity of temperature oscillation of the loop heat pipe increases obviously with the increase of charging ratio of working fluid. In addition
compared with the loop heat pipe with methanol as working fluid
the system using acetone with lower latent heat has a smaller range of heat load in which temperature oscillation exists and the severity of temperature oscillation decreases clearly.
MAYDANIK Y F. Loop heat pipes[J]. Appl Thermal Eng, 2005, 25(6):635-657.
STEPHANE L, VALERIE S, JOCELYN B. Parametric analysis of loop heat pipe operation: a literature review[J]. Int J Thermal Sci, 2007, 46(7):621-636.
VERSHININ S V, MAYDANIK Y F. Investigation of pulsations of the operating temperature in a miniature loop heat pipe[J].Int J Heat Mass Transfer, 2007, 50(25):5232-5240.
KU J, OTTENSTEIN L, KOBEl M, et al. Temperature oscillations in loop heat pipe operation[J].AIP Conf Proc, 2001, 552(1):255-262.
GONCHAROV K A, KOTLYAROV E Y, SMIRNOV F Y. Investigation of temperature fluctuation in loop heat pipes, SEA paper 941577[R]. Friedrichshafen, Germany: SEA International, 1994.
KAYA T, KU J. Thermal operational characteristics of a small loop heat pipe[J]. J Thermophys Heat Transfer, 2003, 17(4):464-470.
SINGH R, AKBARZADEH A, Mochizuki M. Operational characteristics of a miniature loop heat pipe with flat evaporator[J]. Int J Thermal Sci, 2008, 47(11):1504-1515.
张红星, 林贵平, 丁汀,等. 环路热管温度波动现象的实验分析[J].北京航空航天大学学报, 2005, 31(2): 116-120.
ZHANG Hongxing, LIN Guiping, DING Ding, et al. Experimental investigation on temperature oscillation of loop heat pipes[J]. Journal of Beijing University of Aeronautics and Astronautics, 2005, 31(2): 116-120.
林贵平,李楠,张红星.环路热管的地面实验研究现状[J].航空动力学报,2008, 23(8):1387-1396.
LIN Guiping, LI Nan, ZHANG Hongxing. State-of-the-art of ground-experiments of loop heat pipe[J]. Journal of Aerospace Power, 2008, 23(8):1387-1396.
林宗虎,王树众,王栋. 气液两相流和沸腾传热[M]. 西安:西安交通大学出版社,2003.
盖德·希特斯洛尼.多相流动和传热手册[M]. 鲁钟琪,等译. 北京:机械工业出版社,1993.
罗森诺 W M. 传热学手册[M]. 李荫亭,等译. 北京:科学出版社,1987.