提出了一种基于线路两端电压差的输电线路相位纵联保护.根据分相阻抗的相角特性
相位值是由线路各相两个等效电压故障分量差的比值计算而来的
利用这个比值的相位判断故障是否发生在保护区内.当比值的相位等于0°时表明为区外故障
当比值的相位等于180°时表明为区内故障.该保护动作灵敏、适应性强
具备较强的抵御线路电容的特性
可不经过补偿
直接运用于绝大多数输电线路的纵联保护中
同时可有效抵御区外故障时电流互感器(TA)饱和的影响.EMTP数字仿真和动模仿真结果验证了该保护的有效性.
A phase pilot protection of transmission line based on the voltage difference between both terminals is proposed. According to the angle characteristics of the individual phase impedance
the phase value is evaluated by the ratio of the two equivalent differences of the fault-superimposed components of voltage at each phase of the line
then whether the fault occurred in the protected region is judged. When the phase values just equal to 0°
the fault appears outside of the protected zone
and the fault is inside of the protected zone when they equal to 180°. The proposed protection with identity of sensitive operation and adaptation is capable of resisting the line capacitors
and can be directly used in pilot protections of most transmission lines without compensation. The EMTP simulation and the dynamic simulation show the effectiveness.
葛耀中. 新型继电保护和故障测距的原理与技术[M]. 2版. 西安:西安交通大学出版社, 2007:63-106.
吴大立, 尹项根, 张哲, 等. 输电线路复合差动保护方案[J]. 电网技术, 2008,32(7):87-91.
WU Dali, YIN Xianggen, ZHANG Zhe, et al. Research on multi-differential protection scheme for trans-mission line [J]. Power System Technology, 2008,32(7):87-91.
苗世洪, 刘沛, 程时杰, 等. 750kV输电线路相差保护中的电容电流补偿问题仿真研究[J]. 电网技术, 2008,32(11):54-60.
MIAO Shihong, LIU Pei, CHENG Shijie, et al. Research and simulation of capacitance current compensating countermeasure for phase differential protection of 750 kV transmission lines [J]. Power System Technology, 2008,32(11):54-60.
索南加乐, 夏经德, 阿里木江·卡德尔, 等. 输电线路分相复合阻抗纵联保护新原理 [J]. 中国电机工程学报, 2009,29(31):80-86.
SUONAN Jiale, XIA Jingde, ALIMJAN Kader, et al. A novel transmission line pilot protection principle based on composite impedance of individual phase [J]. Proceedings of the CSEE, 2009,29(31):80-86.
索南加乐, 夏经德, 焦在滨, 等. 故障全量的分相复合阻抗输电线路纵联保护原理[J]. 西安交通大学学报,2010,44(2):92-97.
SUONAN Jiale, XIA Jingde, JIAO Zaibin, et al. Transmission line pilot protection principle of fault total content based on composite impedance of individual phase [J]. Journal of Xi'an Jiaotong University, 2010,44(2):92-97.
交直流混联系统对距离保护暂态超越的影响及解决措施. 西安交通大学学报, 2010,44(4):57-61.
故障全量的分相复合阻抗输电线路纵联保护原理. 西安交通大学学报, 2010,44(2):92-97.
基于模型识别的平行线路零序方向元件. 西安交通大学学报, 2010,44(2):102-107.
双端带并联电抗器的输电线路纵联保护. 西安交通大学学报, 2009,43(10):99-103.
继电保护装置信号端口电磁干扰传播通道的建模与仿真. 西安交通大学学报, 2009,43(10):104-108.
基于模型识别的并联电容器保护. 西安交通大学学报, 2008,42(12):1506-1509.
带可控串补和可调电抗器输电线路纵联保护新原理. 西安交通大学学报, 2008,42(10):1259-1263.
输电线路超高速保护中小波算法的研究. 西安交通大学学报, 2008,42(2):194-198.
变压器漏电感参数在线辨识方法研究. 西安交通大学学报, 2008,42(2):199-203.
基于励磁电感参数识别的变压器励磁涌流判别方法. 西安交通大学学报, 2007,41(12):1214-1218.
一种新的高压线路振荡选相元件. 西安交通大学学报, 2007,41(8):945-953.
一种新型的分布式隐私保护计算模型及其应用. 西安交通大学学报, 2007,41(8):954-958.
基于形态梯度的输电线电流行波比较式超高速保护. 西安交通大学学报, 2007,41(4):484-488.
0
浏览量
4
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621