Overreading Correction of High Pressure Wet Gas Flowrate Measurement Based on Venturi Meter and Gamma Ray Technology[J]. 2020, 54(8): 163-167.
DOI:
Overreading Correction of High Pressure Wet Gas Flowrate Measurement Based on Venturi Meter and Gamma Ray Technology[J]. 2020, 54(8): 163-167.DOI: 10.7652/xjtuxb202008021.
Overreading Correction of High Pressure Wet Gas Flowrate Measurement Based on Venturi Meter and Gamma Ray Technology
Theoretical analysis and experiments based on hori-ontally installed Venturi flow meter and gamma ray sensor are carried out to correct the overreading of wet gas flow measurement caused by the existence of liquid with single differential pressure flow meter. The pipe diameter of experiment is 254 mm
test mediums are nitrogen for gas phase and kerosene for liquid phase. The inlet diameter of Venturi is 172 mm and diameter ratio is 0.58. The gamma sensor is installed at the throat of Venturi for gas void fraction measurement. The quality and gas liquid slip ratio are considered to nonlinearly fit the test data
and a new empirical correction model is obtained. Calculation results from the new model are compared with the results from modes of Murdock and Chisholm. Experimental results show that the overreading corrections calculated by the traditional Murdock and Chisholm models keep high accuracy only when Lockhart-Martinelli parameter ranges from 0.011 to 0.1
while the new empirical
关键词
Keywords
references
American Petroleum Institute. State of the art multiphase flow metering [M]. Washington DC, USA: API Publication, 2004: 23-25.
International Organization for Standardization. Measurement of wet gas flow by means of pressure differential devices inserted in circular cross-section conduits: ISO/TR 11583: 2012 [S/OL]. [2012-05-31]. http:∥doi.org/10.3403/30197318.
ASME. Wet gas flowmetering guideline: MFC-19G-2008 [Z]. New York, USA: American Society of Mechanical Engineers, 2008: 57-58.
FALCONE G, HEWITT G, ALIMONTI C. Multiphase flow metering: principles and applications [M]. Amsterdam, Netherlands: Elsevier, 2009: 19-20.
CHISHOLM D. Research note: two-phase flow through sharp-edged orifices [J]. Archive: Journal of Mechanical Engineering Science, 1977, 19(3): 128-130.
DE LEEUW R. Liquid correction of Venturi meter readings in wet gas flow [C]∥Proceedings of the 1997 North Sea Flow Measurement Workshop. London, UK: Energy Institute, 1998: 153161.
JAMES R. Metering of steam-water two-phase flow by sharp-edged orifices [J]. Proceedings of the Institution of Mechanical Engineers, 1965, 180(1): 549-572.
LIN Zonghu. Two-phase flow measurements with sharp-edged orifices [J]. International Journal of Multiphase Flow, 1982, 8(6): 683-693.
MURDOCK J. Two-phase flow measurement with orifices [J]. Journal of Fluids Engineering, 1962, 84(4): 419-432.
SMITH R, LEANG J. Evaluations of correlations for two-phase, flowmeters three current-one new [J]. Journal of Engineering for Power, 1975, 97(4): 589-593.
STEVEN R, HALL A. Orifice plate meter wet gas flow performance [J]. Flow Measurement and Instrumentation, 2009, 20(4/5): 141-151.
STEVEN R N. Wet gas metering with a horizontally mounted Venturi meter [J]. Flow Measurement and Instrumentation, 2002, 12(5/6): 361-372.
HUA Chenquan, WANG Changming, GENG Yanfeng, et al. Metering correlation of slotted orifice for low-pressure wet gas flow [J]. Journal of Nanjing University of Science and Technology, 2010, 34(1): 91-95.
ZHENG Yongjian, WANG Zhengang, PAN Yanzhi, et al. Study on wet gas flowrate measurement method based on venturi and gamma ray technology [J]. Natural Gas Industry, 2019, 39(9): 117-122.
XU Ying, YUAN Chao, LONG Zhenghai, et al. Research the wet gas flow measurement based on dual-throttle device [J]. Flow Measurement and Instrumentation, 2013, 34: 68-75.
XU Ying, ZHANG Qiang, YU Lei, et al. Wet gas metering using double differential pressure device [J]. Chinese Journal of Scientific Instrument, 2010, 31(8): 1840-1847.
ZHANG Qiang, XU Ying, ZHANG Tao. Wet gas metering based on dual differential pressure of long throat Venturi tube [J]. Journal of Tianjin University, 2012, 45(2): 147-153.
CHARLES B, WALT S, JOSH K. Experimental wet gas data for a Herschel style Venturi [R]. Nunn, Colorado, USA: Colorado Engineering Experiment Station Inc., 1997.
PAN Yanzhi, MA Yugao, HUANG Shanfang, et al. A new model for volume fraction measurements of horizontal high-pressure wet gas flow using gamma-based techniques [J]. Experimental Thermal and Fluid Science, 2018, 96: 311-320.