To improve the ventilation cooling effect of air-cooled hydrogenerators
the design and performance analysis methods of the stator cooling structure are investigated. Taking a 250 MW air-cooled hydrogenerator for example
the factors of stator winding transposition
channel steel
slot wedge shape and the interaction among ventilation ditches are considered to construct the physical model and mathematical model of stator fluid-solid coupling
and the loss of each strand is numerically evaluated. According to fluid heat transfer theory and temperature rise characteristics of the air-cooled hydrogenerator stator
three design strategies are proposed by changing the structural dimensions of the stator cores and the ventilation grooves in the generator. Comparing the fluid and temperature fields in the solution region for different structures
the optimal cooling structure of the generator stator is obtained. The accuracy of the model and the feasibility of the method are experimentally ve
CHEN Feng, LI Hongkai, QIN Peng, et al. Study on the optimization of eddy current losses of end structures for 1 000 MW air-cooled hydro-generator [J]. Water Power, 2018, 44(8): 74-77.
ZHAN Yue, MCLOONE S, CAO Wenping, et al. Power loss and thermal analysis of a MW high speed permanent magnet synchronous machine [J]. IEEE Transactions on Energy Conversion, 2017, 32(4): 1468-1478.
ISTAD M, RUNDE M, NYSVEEN A, et al. A review of results from thermal cycling tests of hydrogenerator stator windings [J]. IEEE Transactions on Energy Conversion, 2011, 26(3): 890-903.
LIANG Yanping, WANG Ying, LIU Yang, et al. Derivation of temperature distribution of stator winding with transposed conductors for a large air-cooled hydrogenerator [J]. IEEE Transactions on Industrial Electronics, 2016, 63(8): 4764-4722.
LU Yiping, GE Yajun, WANG Haoran, et al. Verification and analysis on turbulence model of flow field simulation for multiple ventilation stator ducts of air-cooled turbo generators [J]. Electric Machines and Control, 2018, 22(5): 63-69.
XIONG Bin, GU Guobiao, RUAN Lin, et al. Studies on the structure of radial ventilation channel to improve the cooling capacity of large turbo generator stator [C]∥17th International Conference on Electrical Machines and Systems. Piscataway, NJ, USA: IEEE, 2014: 354-357.
WEN Jiabin, HOU Jian, YU Xiwei. Influence of stator ventilation channel on the temperature field in the middle-size high voltage motor [J]. Electric Machines and Control, 2016, 20(8): 40-47.
DING Shuye, WANG Mengqi. Comparison investigation of fluid rheological characteristics effect on stator temperature field for large hydro-generator based on experiment [J]. The International Journal for Computation and Mathematics in Electrical and Electronic Engineering, 2015, 34(1): 234-247.
ZHOU Chunlei, BIAN Xu, LIANG Yanping, et al. Numerical calculation and analysis of temperature field for stator transposition bar in hydro-generator [J]. International Journal of Thermal Sciences, 2018, 125: 350-357.
DU Canxun, GUI Weihua, ZHOU Guanghou. Excessive losses and temperature field calculation of stator coil bars in air-cooled large hydro-generator [J]. Proceedings of the CSEE, 2012, 32(12): 111-119.
DING Shuye, GUO Baocheng, SUN Zhaoqiong. Ventilation structure optimization and performance analyses of permanent magnet wind generators [J]. Proceedings of the CSEE, 2013, 33(9): 122-128.
HUO Feiyang, LI Yong, LI Weili, et al. Calculation and analysis on stator ventilation structure of different optimum proposal in air-cooled turbogenerator [J]. Proceedings of the CSEE, 2010, 30(6): 69-75.
LIANG Yanping, BIAN Xu, YANG Lichao, et al. Numerical calculation of circulating current losses in stator transposition bar of large hydro-generator [J]. IET Science, Measurement Technology, 2015, 9(4): 485-491.