To improve the thermal performance of industrial heat pumps and realize the high-efficiency recovery of industrial low-temperature residual heat
a double-heat source high-temperature heat pump system with an intermediate heat exchanger is proposed in this paper and the cold water is heated to high temperatures by two stages for industrial application. First
it is heated to the intermediate temperature by CO
2
which absorbs heat from the air
and then
the water is further heated to a high temperature by R152a
taking waste water as the heat source. In the intermediate heat exchanger
the heat of R152a after condensation is recovered by heating CO
2
to the superheated state after evaporation. Thermodynamic analysis was conducted and it was i
ndicated that there exists a highest superheated temperature for CO
2
when the temperature drop of R152a is given in the intermediate heat exchanger
which shows the best performance of this heat pump system. Compared with the single-heat source heat pump by recovering the residual heat of waste water of 50 ℃
the hot water supply is more than double of it; the average power consumption per kg of hot water decreases about 43.2%; and the COP and energy efficiency increase about 41.9% and 23.9% respectively.
关键词
Keywords
references
PATEL K K, KAR A. Heat pump assisted drying of agricultural produce: an overview[J]. Food Sci Technol, 2012, 49(2): 142-160.
CHUA K J, CHOU S K, YANG W M. Advances in heat pump systems: a review[J]. Appl Energy, 2010, 87(10): 3611-3624.
AMMER Y, LI H. Desalination using low grade heat in the process industry: challenges and perspectives[J]. Appl Therm Eng, 2012, 48(2): 446-457.
ZHOU Xiangjiang, LIAN Zhiwei. Feasibility analysis of high temperature using in China[J]. Fluid Machinery, 2003, 31(7): 55-58.
DISA W, SOM J, WONG W. Experimental investigation on the performance of the refrigeration cycle using a two-phase ejector as an expansion device[J]. Refrigeration, 2004, 27(6): 587-594.
LIU Jinping, XU Xiongwen. Experimental study on zeotropic mixture auto-cascade heat pump[J]. Cryogenics, 2007, 34(6): 408-413.
GOKTUN S. Selection of working fluids for high-temperature heat pumps[J]. Energy, 1995, 20(7): 623-625.
DEVOTTA S, PENDYAL A. Thermodynamic screening of some HFCs and HFEs for high-temperature heat pumps as alternative to CFC114[J]. Int J Refrig, 1994, 17(5): 338-342.
PAN L S, WANG H X, CHEN Q Y, et al. Theoretical and experimental study on several refrigerants of moderately high temperature heat pump[J]. Applied Thermal Engineering, 2011, 31(11): 1886-1893.
GAO Pan, ZHAO Li. Investigation on incomplete condensation of non-azeotropic working fluids in high temperature heat pumps[J]. Energy Conversion and Management, 2006, 47(4): 1884-1893.
WANG Kai, CAO Feng, XING Ziwen. Development and experimental validation of high temperature heat pump for heat recovery[J]. Journal of Xi'an Jiaotong University, 2008, 4(10): 1309-1312.
SARKAR J, BHATTACHARYYA S. Optimization of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications[J]. International Journal of Refrigeration, 2004, 27(8): 830-838.
XU Xiaoxiao, CHEN Guangming, TANG Liming, et al. Experiment on performance of transcritical CO2 heat pump water heater system with ejector[J]. Journal of Xi'an Jiaotong University, 2009, 43(11): 51-55.
LEMMON E W, HUBER M L, MCLINDEN M O. NIST reference fluid thermodynamics and transport properties: REFPROP, NIST standard reference standard reference database23[DB]. Version 7.1. Boulder, USA: National Institute of Standard and Technology, 2010.