An Electroencephalograph Source Localization Algorithm Based on Wavelet Packet Transform with Simulation[J]. 2013, 47(12): 130-136.
DOI:
An Electroencephalograph Source Localization Algorithm Based on Wavelet Packet Transform with Simulation[J]. 2013, 47(12): 130-136.DOI: 10.7652/xjtuxb201312022.
An Electroencephalograph Source Localization Algorithm Based on Wavelet Packet Transform with Simulation
A new algorithm of electroencephalograph(EEG)source localization based on wavelet packet transform is proposed to obtain the neural electrical activity distribution of brain. Conducting wavelet packet decomposition for neural electrical signals
subspace component selection and signal reconstruction
an inverse problem with a MRI-based three-layer head model is solved. A comparative investigation includes signal-to-noise ratio(SNR)
dipole source depth and electrode number. The results indicate that in different circumstances
the average distances between the reconstructed sources of the proposed algorithm and the setting sources get less than 3 mm
and the standard deviations about 1 mm
while the average distances and the standard deviations of the existing algorithm achieve up to 9.4 mm and 4.5 mm
respectively; in the same circumstances
the means and standard deviations of the proposed algorithm get less than that of the algorithm
and can be reduced by up to 6.6 mm and 3.5 mm
respectively. The proposed algorithm is endowed with better localization accuracy and enhanced robustness than the existing algorithm(P<0.05)to show the clinical significance.
关键词
Keywords
references
ELSHOFF L, GROENING K, GROUILLER F, et al. The value of EEG-fMRI and EEG source analysis in the presurgical setup of children with refractory focal epilepsy [J]. Epilepsia, 2012, 53(9): 1597-1606.
WANG G, WORRELL G, YANG L, et al. Interictal spike analysis of high-density EEG in patients with partial epilepsy [J]. Clin Neurophysiol, 2011, 122(6): 1098-1105.
XU Peng, YAO Dezhong, CHEN Huafu. A novel EEG source localization method based on FOCUSS iteration procedure combined with lp norm sparse constraints [J]. Acta Electronica Sinica, 2006, 34(1): 55-58.
WOLTERS C H, ANWANDER A, TRICOCHE X, et al. Influence of tissue conductivity anisotropy on EEG/MEG field and return current computation in a realistic head model: a simulation and visualization study using high-resolution finite element modeling [J]. NeuroImage, 2006, 30(3): 813-826.
RULLMANN M, ANWANDER A, DANNHAUER M, et al. EEG source analysis of epileptiform activity using a 1 mm anisotropic hexahedra finite element head model [J]. NeuroImage, 2009, 44(2): 399-410.
WU Qing, SONG Zhaoyun, LI Ying, et al. Reconstruction of 3D EEG sources distribution by computer simulation [J]. Computer Simulation, 2003, 20(5): 74-77.