The orthogonal experiment design was performed to investigate the effects of the jet velocity
the jet angle
the jet slot width
the commutated plate area and the range hood flow rate on the performance of the range hood and the kitchen environment for the range hood with a jet air curtain and a commutated plate. The optimum design parameters of the air curtain were obtained. The results show that
coupled with the commutated plate
the air curtain with the optimum parameters can effectively control the movement of the high temperature air with oil fume in the kitchen. The range hood flow rate has a significant influence on the temperature distribution and the oil fumes concentration. For the range hood studied
the optimum value of the flow rate
the commutated plate area
the jet velocity
the jet angle
and the jet slot width are 10.5 m
3
/min
0.22 m
2
1.5 m/s
-5°
an
d 4 mm
respectively.
关键词
Keywords
references
SEE S W, BALASUBRAMANIAN R. Risk assessment of exposure to indoor aerosols associated with Chinese cooking [J]. Environmental Research, 2006, 102(2): 197-204.
LAI A C K, CHEN F Z. Modeling of cooking-emitted particle dispersion and deposition in a residential flat: a real room application [J]. Building and Environment, 2007, 42(9): 3253-3260.
LAI A C K, HO Y W. Spatial concentration variation of cooking-emitted particles in a residential kitchen [J]. Building and Environment, 2008, 43(5): 871-876.
SILVERMAN L. Centerline velocity characteristics of round openings under suction [J]. Journal of Industrial Hygiene and Toxicology, 1942, 24: 259-266.
HUANG R F, SIR S Y, CHEN Y K, et al. Capture envelopes of rectangular hoods in cross drafts [J]. American Industrial Hygiene Association, 2001, 62(5): 563-572.
TSAI S J, HUANG R F, ELLENBECKER M J. Airborne nanoparticle exposures while using constant-flow, constant-velocity, and air-curtain-isolated fume hoods [J]. Annals of Occupational Hygiene, 2011, 54(1): 78-87.
HUANG R F, LIN S Y, JAN S Y, et al. Aerodynamic characteristics and design guidelines of push-pull ventilation systems [J]. The Annals of Occupational Hygiene, 2005, 49(1): 1-15.
HWANG R L, LIN T P, LIANG H H, et al. Additive model for thermal comfort generated by matrix experiment using orthogonal array [J]. Building and Environment, 2009, 44(8): 1730-1739.
GONG G C, XU C W, JIAO J J, et al. Investigation of moisture condensation on paper-making plant envelopes in high humidity environment by orthogonal analysis and CFD simulation [J]. Building and Environment, 2011, 46(8): 1639-1648.
SAS IP Inc. ANSYS 13. 0 theory guide [M]. Canonsburg, USA: ANSYS Inc., 2010.