The two-phase flow coefficient of a V-cone meter was proposed to correct the “over-reading” produced by measuring the wet gas using the V-cone meter. The experiment was conducted with the V-cone meter with a diameter ratio of 0.75 for air and water. The test pressure ranged from 0.10 MPa to 0.22 MPa
and the gas and liquid mass flow rates were from 100 m
3
·h
-1
to 300 m
3
·h
-1
and from 0 to 0.08 m
3
·h
-1
respectively. The effects of the Lockhart-Martinelli parameter
the operating pressure and the gas densiometric Froude number on the two-phase flow coefficient were investigated. The results show that the two-phase flow coefficient increased linearly with the Lockhart-Martinelli parameter
and the slope of the two-phase flow coef
ficient vs. the Lockhart-Martinelli parameter was affected by the gas densiometric Froude number and the pressure. The correlation between the two-phase flow coefficient and the Lockhart-Martinelli parameter
the gas densiometric Froude number and the pressure was obtained. On the basis of the two-phase flow coefficient
the wet gas model was developed. The relative error of the gas mass flow rate predicted by the model is within ±5.0% at the 95% confidence level.
关键词
Keywords
references
ASME. Wet gas flowmetering guideline, MFC-19G-2008 [R]. New York, USA: The American Society of Mechanical Engineers, 2008: 1-74.
LAWRENCE P A. Wet gas measurement [C]∥Proceedings of the 84th International School of Hydrocarbon Measurement. Colorado, USA: CEESI, 2009: 165-179.
XU L J, ZHOU W L, LI X M. Wet gas flow modeling for a vertically mounted Venturi meter [J]. Measurement Science and Technology, 2012, 23(4): 045301.
GYSLING D L, LOOSE D H, VOLZ R. Wet gas metering using combination of differential pressure and SONAR flow meters [C]∥Proceedings of the 24th International North Sea Flow Measurement Workshop. Glasgow, UK: TUV NEL, 2006: 410-417.
MURDOCK J. Two-phase flow measurement with orifices [J]. ASME Journal of Basic Engineering, 1962, 84: 419-433.
SMITH R V, LEANG J T. Evaluations of correlations for two-phase, flowmeters three current-one new [J]. ASME Journal of Engineering Power, 1975, 97(4): 589-593.
LIN Z H. Two-phase flow measurements with sharp-edged orifices [J]. International Journal of Multiphase Flow, 1982, 8(6): 683-693.
DE LEEUW R. Liquid correction of Venturi meter readings in wet gas flow [C]∥Proceedings of the 1997 North Sea Flow Measurement Workshop. London, UK: Energy Institute, 1998: 153-161.
STEVEN R N. Wet gas metering with a horizontally mounted Venturi meter [J]. Flow Measurement and Instrumentation, 2002, 12(5): 361-372.
GENG Yanfeng, FENG Shuchu, ZHENG Jinwu, et al. Metering technology for condensate natural gas [J]. Process Automation Instrumentation, 2005, 26(8): 1-3.
STEVEN R, LAWRENCE P A. Research developments in wet gas metering with V-Cone meters [C]∥Proceedings of the 21st North Sea Flow Measurement Workshop. London, UK: Energy Institute, 2008: 174-193.
STEWART D G, STEVEN R, PETERS R J W. Wet gas metering with V-Cone meters [C]∥Proceedings of the 20th North Sea Flow Measurement Workshop. Glasgow, UK: TUV NEL, 2002: 194-212.
HU Jun, DONG Feng. Research on measurement of air/water two-phase flow based on V-Cone flowmeter [J]. Journal of Engineering Thermophysics, 2007, 28(S1): 205-208.
XU Ying, ZHANG Qiang, YU Lei, et al. Measurement technology of the condensate natural gas two-phase flow by non-separation [J]. Processing and Utilization, 2011, 31(4): 1-5.
ZHANG F, DONG F, TAN C. High GVF and low pressure gas-liquid two-phase flow measurement based on dual-cone flowmeter [J]. Flow Measurement and Instrumentation, 2010, 21(3): 410-417.
MANDHANE J, GREGORY G, AZIZ K. A flow pattern map for gas-liquid flow in horizontal pipes [J]. International Journal of Multiphase Flow, 1974, 1(4): 537-553.