A-weighted sound pressure level does not fully satisfy the requirements of sound quality evaluation of electro-mechanical products. According to the noise analysis of frequency conversion compressor
an experiential formula of psychoacoustics annoyance is established considering loudness and sharpness synthetically
a pair-wise comparison method is proposed for subjective evaluation
and a pre-estimated model of sound quality subjective evaluation is obtained based on the linear correlation analysis. The research results indicate that the annoyance is more sensitive than dB(A)in sound quality evaluation
the correlation between psychoacoustics annoyance and subjective evaluation approaches to 0.917 3
exceeding remarkably 0.711 9 of dB(A). The psychoacoustics annoyance is reasonable to serve as a comprehensive index of sound quality evaluation for reflecting the real influence of noiseon a person.
SHI Yan, BI Fengrong, LIN Manqun,et al. Basic psychoacoustics theoretics and its application in sound-quality evaluation [J]. Small Internal Combustion Engine Motorcycle, 2006,35(1):57-60.
WANG Dengfeng, LIU Zongwei, LIANG Jie,et al. Subjective evaluation test and objective quantificational description of vehicle interior noise quality [J]. Journal of Jilin University(Engineering and Technology Edition), 2006,36(2):41-45.
JIN Yong Jeon. Sound radiation and sound quality characteristics of refrigerator noise in real living environments [J]. Applied Acoustics,2007,68(10):41-45.
张明铎. A计权声级在噪声测量与评价中的不足[J]. 声学技术,1995,14(1):41-42.
ZHANG Mingduo. Deficiency of A-weighted sound pressure level in measurement and evaluation of noise [J]. Acoustics Technology, 1995,14(1):41-42.
FASTL H. The psychoacoustics of sound quality evaluation [J]. Acta Acoustica, 1997,83(5):754-764.
LIM T C. Correlations between deficiencies in power window systems influencing sound quality and some psychoacoustic metrics [J]. Applied Acoustics,2001,62(9):1025-1047.