Experimental Study on Pool Boiling Heat Transfer of R134a-Oil Mixture Outside Single Horizontal Enhanced Tubes
|更新时间:2025-12-08
|
Experimental Study on Pool Boiling Heat Transfer of R134a-Oil Mixture Outside Single Horizontal Enhanced Tubes
Vol. 42, Issue 5, Pages: 519-523(2008)
作者机构:
1. 西安交通大学能源与动力工程学院,西安,710049
2. 大连交通大学机械工程学院,大连,610028
作者简介:
基金信息:
DOI:
CLC:TK172
Online First:10 May 2008,
Published:2008
稿件说明:
移动端阅览
费继友 1, 2, 张定才 1, et al. Experimental Study on Pool Boiling Heat Transfer of R134a-Oil Mixture Outside Single Horizontal Enhanced Tubes[J]. 2008, 42(5): 519-523.
DOI:
费继友 1, 2, 张定才 1, et al. Experimental Study on Pool Boiling Heat Transfer of R134a-Oil Mixture Outside Single Horizontal Enhanced Tubes[J]. 2008, 42(5): 519-523.DOI:
Experimental Study on Pool Boiling Heat Transfer of R134a-Oil Mixture Outside Single Horizontal Enhanced Tubes
heat transfer coefficients were experimentally determined for three horizontal enhanced tubes(E21
E22
E23)with R134a-oil mixture. The evaporation temperature was 10 ℃ and 5 ℃
respectively and the water velocity inside enhanced tubes was ranged from 1.5 m/s to 3.5 m/s. The results show that compared with smooth tube the enhancement magnification of heat transfer coefficient inside E21
E22 and E23 is 3.703
3.035 and 2.709
respectively. The heat transfer coefficients outside the tubes with the oil concentration of 100×10
-6
increase by 3.7%-7.2% compared with those with oil concentration of 50×10
-6
at the same water velocities and the evaporation temperature 5 ℃
while by 0.8%-10.9% at the evaporation temperature 10 ℃.
DING Rui, ZHENG Gang, SONG Ji. Research review of lubricant oil's impact on in-tube flow boiling heat transfer [J]. Fluid Machinery, 2006,34(16):80-85.
SCHLAGER L M, PATE M B, BERGLES A E. Heat transfer and pressure drop performance of smooth and internally finned tubes with oil and refrigerant 22 mixtures [J]. ASHRAE Trans, 1989, 95: 160-169.
ECKELS S J, DOERR T M, PATE M B. Heat transfer coefficients and pressure drops for R2134a and an ester lubricant mixture in a smooth tube and a micro-fin tube [J]. ASHRAE Trans, 1998, 104: 366-375.
CAWTE H, SANDERS D A, POLAND G A. Effect of lubricating oil contamination on evaporation in refrigerants R12 and R22 [J]. Int J of Energy Research, 1996, 20(8):663-679.
ZURCHER O, THOME J R, FAVRAT D. Flow boiling and pressure drop measurements for R2134a/oil mixtures: evaporation in a plain tube [J]. HVACR Research, 1997, 3(1): 54-64.
YAN Jia, TONG Mingwei, YANG Peng. An experimental investigation on evaporation heat transfer and pressure drop of HC290-oil mixtures in a horizontal micro-fin tube [J]. Journal of Refrigeration, 2005, 26(1):5-10.
WEI Wenjian, HU Haitao, DING Guoliang, et al. Experimental study on the influence of oil on heat transfer performance of refrigerant flow boiling inside small tubes [J]. Journal of Shanghai Jiaotong University, 2006,40(2): 286-290.
WEBB R L, RUDY T M,KEDZIERSKI M A. Prediction of the condensation coefficient on horizontal integral-fin tubes [J].ASME Journal of Heat Transfer, 1985, 107(2): 369-376.
SUKHATME S P, JAGADISH B S, PRABHAKARAN P.Film condensation of R11 vapor on single horizontal enhanced condenser tubes [J]. ASME Journal of Heat Transfer, 1990,112(1): 229-234.
蒋能照. 新制冷工质热力性质图和表 [M]. 上海:上海交通大学出版社,1992.
杨世铭, 陶文铨. 传热学 [M].4版. 北京:高等教育出版社,2006.
GNIELINSKI V. New equations for heat and mass transfer in turbulent pipe and channel flow [J]. Int Chemical Engineering, 1976, 16(2): 359-368.
CHENG Bing, TAO Wenquan. Experimental study of R152a film condensation on single horizontal smooch tube and enhanced tubes [J]. ASME J Heat Transfer,1994,16(2): 266-270.
KLIME S J, MCCLINTOCK F A. Description of uncertainties in single sample experiments [J]. Mechanical Engineering, 1953,75(1): 3-9.