New corresponding-temperature and corresponding-density were defined for calculating saturated liquid density of refrigerant mixtures. It is found that the relationship between saturated liquid corresponding-density and corresponding-temperature for refrigerant mixtures accorded with that for pure-components. The characteristic densities were calculated with three methods and the generalized equation was achieved to calculate saturated liquid density of refrigerant mixtures. In addition
the calculated values by the equation were compared with the values in literature for five ternary and binary refrigerant mixtures. Their deviations were less than 1.5% for method(1)and method(2)
and less than 2% for method(3). The accuracy can meet the requirements of engineering applications.
Duan Yuanyuan,Xu Jianfeng.A new equation of state for HFC-227ea over entire region[J].Journal of Engineering Thermophysics,2003,24(1):22-24.
Wang Huei Tung, Tsai Jung Chin, Chen Yan Ping.A cubic equation of state for vapor-liquid equilibrium calculations of nonpolar and polar fluids[J].Fluid Phase Equilib,1997,138(1/2):43-59.
Chen Zeshao,Hu Peng,Chen Jianxin,et al.Predication of saturated vapor pressure of non-azeotropic mixtures up to the critical region[J].Journal of Engineering Thermophysics,2006,27(3):388-390
Chen Zeshao, Chen Jianxin, Hu Peng. The calculation of bubble-point and dew-point for multivariant mixtures[J]. Journal of Engineering Thermophysics, 2006,27(Suppl.1):41-44.
Chen Zeshao,Cheng Wenlong,Hu Peng.A generalized prediction equation for saturated liquid density[J].Journal of Engineering Thermophysics,2001,22(suppl):9-12.
Tillner-Roth R,Li Jin,Yokozeki A,et al.Thermodynamic properties of pure and blended hydrofluorocarbon(HFC)fefrigerants[M].Tokyo:Japan Society of Refrigerating and Air Conditioning Engineers,1998:135-810.
Japanese Association of Refrigeration.JAR Handbook Fundament[M].5th ed.Tokyo:Japanese Association of Refrigeration,1993:170-211.