A transparent model based on a BCD-190W type frost-free refrigerator was constructed with organic glass
and the experiment system for measuring the air flow characters in the cooling chamber of the model was built. Using digital particle image velocimetry(DPIV)technology
the mean velocities distributions on the typical 2-D zones in the cooling chamber of the model were measured. The experiment results show that the air flow velocities and air flow rates at the supply-air openings were non-uniform. The air flow velocities at the openings in the top chest were the largest in the four chests
and those in the fourth chest were somewhat lower. Moreover
the air velocities at the openings in the second and third chests were less than 0.1 m/s
and thus the flow rates could not meet the function requirement of the chests. Through the analysis of the velocities distributions
the practicability of using DPIV system to measure the flow characters in the chests of the model were verified
and the shortages of the air velocities and flow rates design were discovered. The measurement results also indicate that the resistance and flow rates design for the air flow ducts are the key factors for the refrigerator design.
关键词
Keywords
references
Radermacher R, Kin K. Domestic refrigerators: recent developments [J]. International Journal of Refrigeration, 1996, 19(1):61-69.
Zhou Qin, Pannock J, Raderamcher R. Development and testing of a high efficiency refrigerator [J]. ASHRAE Trans, 1994, 100:1351-1358.
Asano A, Takenaka N, Fujii T, et al. Application of neutron radiography to a diagnosis of refrigerator [J]. Nuclear Instruments and Methods in Physics Research: Section A, 1996, 377:170-173.
Que Xiongcai, Yu Bing, Cheng Zhijiu. Study on characteristics of air tunnel resistance vs flow rate distribution in indirect-cool refrigerator [J]. Journal of Shanghai Jiaotong University,1997, 31(3):13-16.
丁国良, Oellrich L R. 冰箱中空气流场和温度场的有限元模拟[J]. 上海交通大学学报, 1998,32(7):18-22.
Ding Guoliang, Oellrich L R. Simulation of air flow and temperature field inside a refrigerated chamber with finite element method [J]. Journal of Shanghai Jiaotong University,1998, 32(7):18-22.
Yu Bingfeng, Fei Jiyou, Meng Xiangzhao, et al. DPIV measurement and numerical simulation of the inner flow field of freezer chest of frost-free refrigerator [J]. Journal of Refrigeration, 2003, 24(2):32-36.
俞炳丰. 制冷与空调应用新技术[M]. 北京:化学工业出版社,2002.
康琦,申功炘. 全场测速技术进展[J]. 力学进展, 1997, 27(1):106-120.
Kang Qi, Shen Gongxin. Development of the full flow field measurement [J]. Advances in Mechanics, 1997, 27(1):106-120.
Zhang Wei, Wang Yuan, Xu Zhong, et al. Application of particle image velocimetry to measurement of Poisoeullie flow and flow around a circular cylinder [J]. Journal of Xi'an Jiaotong University, 2002, 36(3):246-251.