Pulse Extraction for Partial Discharge with Double Channels with Independent Component Analysis
|更新时间:2025-12-08
|
Pulse Extraction for Partial Discharge with Double Channels with Independent Component Analysis
Vol. 42, Issue 10, Pages: 1264-1268+1294(2008)
作者机构:
西安交通大学电气工程学院,西安,710049
作者简介:
基金信息:
DOI:
CLC:TM835.4
Online First:10 October 2008,
Published:2008
稿件说明:
移动端阅览
司文荣, 李军浩, 梁永春, et al. Pulse Extraction for Partial Discharge with Double Channels with Independent Component Analysis[J]. 2008, 42(10): 1264-1268+1294.
DOI:
司文荣, 李军浩, 梁永春, et al. Pulse Extraction for Partial Discharge with Double Channels with Independent Component Analysis[J]. 2008, 42(10): 1264-1268+1294.DOI:
Pulse Extraction for Partial Discharge with Double Channels with Independent Component Analysis
and solution of basic independent component analysis(ICA)model are briefly introduced. According to the features of white noise(gaussian)and partial discharge(PD)signals(supergaussian)on the probability distribution of magnitude
and the IEC 60270 standard PD measurement method
it indicates that the basic ICA model is feasible to suppress white noise of PD pulse signals. The simulation and on field tests for PD pulses extraction using ultra-wideband(UWB)detection technique with double channels are carried out
respectively. And the ambiguities elimination method for ICA model to extract PD pulses under HVDC is also presented. The results show that PD pulses are able to be exactly extracted from the strong white noise with keeping PD pulses amplitude of the relative relationship
the maximum amplitude corresponding to the time point
and the other important information of PD pulses.
关键词
Keywords
references
CONTIN A, CAVALLINI A, MONTANARI G C. Digital detection and fuzzy classification of partial discharge signals[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2002, 9(3): 335-348.
MA X, ZHOU C, KEMP I J. Interpretation of wavelet analysis and it's application in partial discharge detection[J]. IEEE Trans Dielect Elect Insul, 2002,9(2): 446-457.
LI Li, QU Liangsheng. Independent component analysis for features extraction of machine condition[J]. Journal of Xi'an Jiaotong University, 2003, 37(1): 45-48.
SI Wenrong, LI Junhao, LI Yanming, et al. Preliminary study on signal extraction technology for PD pulse based on independent component analysis [J].High Voltage Engineering, 2008, 34(6): 1277-1282.
PETER H F, JOHAN J. Partial discharges at dc voltage: their mechanism, detection and analysis[J]. IEEE Trans on Dielectrics and Electrical Insulation, 2005, 12(2): 328-340.
SI Wenrong, LI Junhao, LI Yanming, et al. Measurement and analysis for pulse current shapes of partial discharge in oil under DC voltage[J]. Journal of Xi'an Jiaotong University, 2008, 42(4): 481-486.