[1]闫嘉钰,洪毅,潘艳芝,等.基于文丘里和射线技术的高压湿气虚高修正[J].西安交通大学学报,2020,54(08):163-167.[doi:10.7652/xjtuxb202008021]
 YAN Jiayu,HONG Yi,PAN Yanzhi,et al.Overreading Correction of High Pressure Wet Gas Flowrate Measurement Based on Venturi Meter and Gamma Ray Technology[J].Journal of Xi'an Jiaotong University,2020,54(08):163-167.[doi:10.7652/xjtuxb202008021]
点击复制

基于文丘里和射线技术的高压湿气虚高修正
分享到:

《西安交通大学学报》[ISSN:0253-987X/CN:61-1069/T]

卷:
54
期数:
2020年第08期
页码:
163-167
栏目:
出版日期:
2020-08-10

文章信息/Info

Title:
Overreading Correction of High Pressure Wet Gas Flowrate Measurement Based on Venturi Meter and Gamma Ray Technology
文章编号:
0253-987X(2020)08-0163-05
作者:
闫嘉钰1 洪毅1 潘艳芝23 牛棚满3
1.中海油研究总院有限责任公司, 100028, 北京; 2.海默科技(集团)股份有限公司, 730010, 兰州; 3.西安交通大学动力工程多相流国家重点实验室, 710049, 西安
Author(s):
YAN Jiayu1 HONG Yi1 PAN Yanzhi23 NIU Pengman3
1. CNOOC Research Institute, Beijing 100028, China; 2. Haimo Technologies Co. Ltd., Lanzhou 730010, China; 3. State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
关键词:
湿气 虚高 伽马射线 文丘里管
Keywords:
wet gas overreading gamma ray Venturi meter
分类号:
O359+.1
DOI:
10.7652/xjtuxb202008021
文献标志码:
A
摘要:
为了修正仅用单一节流件测量湿气时因液相存在而导致测量结果虚高的问题,利用水平文丘里管结合伽马射线技术开展了理论分析和实验研究。实验系统管道直径254 mm,实验工质气相为氮气,液相为煤油。水平安装的文丘里管入口内径为172 mm,直径比为0.58,以喉部设置的伽马射线测量装置测量截面含气率。考虑干度和气液滑速比的影响,基于实验数据进行非线性拟合,提出了新的虚高修正计算模型,并将新模型计算结果同Murdock和Chisholm虚高修正模型进行了对比分析,结果表明:Murdock和Chisholm模型仅能在Lockhart-Martinelli参数位于0.001~0.1的范围内时,与虚高具有高精度线性关系,而新模型能够在Lockhart-Martinelli参数位于0.001~0.275的范围内时,始终与虚高具有高精度线性关系。新模型所需参数均可现场实时测量,具有计算简便、适用范围更宽的特点。
Abstract:
Theoretical analysis and experiments based on horizontally installed Venturi flow meter and gamma ray sensor are carried out to correct the overreading of wet gas flow measurement caused by the existence of liquid with single differential pressure flow meter. The pipe diameter of experiment is 254 mm, test mediums are nitrogen for gas phase and kerosene for liquid phase. The inlet diameter of Venturi is 172 mm and diameter ratio is 0.58. The gamma sensor is installed at the throat of Venturi for gas void fraction measurement. The quality and gas liquid slip ratio are considered to nonlinearly fit the test data, and a new empirical correction model is obtained. Calculation results from the new model are compared with the results from modes of Murdock and Chisholm. Experimental results show that the overreading corrections calculated by the traditional Murdock and Chisholm models keep high accuracy only when Lockhart-Martinelli parameter ranges from 0.011 to 0.1, while the new empirical correction model keeps linear relationship with overreading in a larger range of Lockhart-Martinelli parameter from 0.011 to 0.275. Parameters of the new model are easy to be measured and adapts to larger range of Lockhart-Martinelli, and is more suitable for practical use.

参考文献/References:

[1] American Petroleum Institute. State of the art multiphase flow metering [M]. Washington DC, USA: API Publication, 2004: 23-25.
[2] International Organization for Standardization. Measurement of wet gas flow by means of pressure differential devices inserted in circular cross-section conduits: ISO/TR 11583: 2012 [S/OL]. [2012-05-31]. http:∥doi.org/10.3403/30197318.
[3] ASME. Wet gas flowmetering guideline: MFC-19G-2008 [Z]. New York, USA: American Society of Mechanical Engineers, 2008: 57-58.
[4] 薛君昭. 湿气管道内腐蚀剩余寿命预测 [D]. 北京: 中国石油大学(北京), 2016: 25-26.
[5] FALCONE G, HEWITT G, ALIMONTI C. Multiphase flow metering: principles and applications [M]. Amsterdam, Netherlands: Elsevier, 2009: 19-20.
[6] CHISHOLM D. Research note: two-phase flow through sharp-edged orifices [J]. Archive: Journal of Mechanical Engineering Science, 1977, 19(3): 128-130.
[7] DE LEEUW R. Liquid correction of Venturi meter readings in wet gas flow [C]∥Proceedings of the 1997 North Sea Flow Measurement Workshop. London, UK: Energy Institute, 1998: 153161.
[8] JAMES R. Metering of steam-water two-phase flow by sharp-edged orifices [J]. Proceedings of the Institution of Mechanical Engineers, 1965, 180(1): 549-572.
[9] LIN Zonghu. Two-phase flow measurements with sharp-edged orifices [J]. International Journal of Multiphase Flow, 1982, 8(6): 683-693.
[10] MURDOCK J. Two-phase flow measurement with orifices [J]. Journal of Fluids Engineering, 1962, 84(4): 419-432.
[11] SMITH R, LEANG J. Evaluations of correlations for two-phase, flowmeters three current-one new [J]. Journal of Engineering for Power, 1975, 97(4): 589-593.
[12] STEVEN R, HALL A. Orifice plate meter wet gas flow performance [J]. Flow Measurement and Instrumentation, 2009, 20(4/5): 141-151.
[13] STEVEN R N. Wet gas metering with a horizontally mounted Venturi meter [J]. Flow Measurement and Instrumentation, 2002, 12(5/6): 361-372.
[14] 华陈权, 王昌明, 耿艳峰, 等. 槽式孔板低压湿气计量修正模型 [J]. 南京理工大学学报(自然科学版), 2010, 34(1): 91-95.
HUA Chenquan, WANG Changming, GENG Yanfeng, et al. Metering correlation of slotted orifice for low-pressure wet gas flow [J]. Journal of Nanjing University of Science and Technology, 2010, 34(1): 91-95.
[15] 谭晋飞. 湿气流量测量虚高特性实验研究 [D]. 天津: 天津大学, 2014: 30-33.
[16] 郑永建, 王镇岗, 潘艳芝, 等. 基于文丘里管和射线技术的低压湿气测量方法 [J]. 天然气工业, 2019, 39(9): 117-122.
ZHENG Yongjian, WANG Zhengang, PAN Yanzhi, et al. Study on wet gas flowrate measurement method based on venturi and gamma ray technology [J]. Natural Gas Industry, 2019, 39(9): 117-122.
[17] XU Ying, YUAN Chao, LONG Zhenghai, et al. Research the wet gas flow measurement based on dual-throttle device [J]. Flow Measurement and Instrumentation, 2013, 34: 68-75.
[18] 徐英, 张强, 于磊, 等. 利用双差压式节流装置测量湿气 [J]. 仪器仪表学报, 2010, 31(8): 1840-1847.
XU Ying, ZHANG Qiang, YU Lei, et al. Wet gas metering using double differential pressure device [J]. Chinese Journal of Scientific Instrument, 2010, 31(8): 1840-1847.
[19] 张强, 徐英, 张涛. 基于长喉径文丘里管的双差压湿气流量测量 [J]. 天津大学学报, 2012, 45(2): 147-153.
ZHANG Qiang, XU Ying, ZHANG Tao. Wet gas metering based on dual differential pressure of long throat Venturi tube [J]. Journal of Tianjin University, 2012, 45(2): 147-153.
[20] CHARLES B, WALT S, JOSH K. Experimental wet gas data for a Herschel style Venturi [R]. Nunn, Colorado, USA: Colorado Engineering Experiment Station Inc., 1997.
[21] PAN Yanzhi, MA Yugao, HUANG Shanfang, et al. A new model for volume fraction measurements of horizontal high-pressure wet gas flow using gamma-based techniques [J]. Experimental Thermal and Fluid Science, 2018, 96: 311-320.

相似文献/References:

[1]贺登辉,柳海,张锋,等.V锥流量计湿气流量测量新模型[J].西安交通大学学报,2013,47(01):032.[doi:10.7652/xjtuxb201301007]
 HE Denghui,LIU Hai,ZHANG Feng,et al.A New Model for Wet Gas Flow Measurement with V-Cone Meter[J].Journal of Xi'an Jiaotong University,2013,47(08):032.[doi:10.7652/xjtuxb201301007]

备注/Memo

备注/Memo:
收稿日期: 2020-02-16。作者简介: 闫嘉钰(1988—),男,高级工程师; 潘艳芝(通信作者),女,高级工程师。基金项目: 国家“十三五”重大专项资助项目(2016ZX05028-003-004)。
更新日期/Last Update: 2020-08-10